TODAY: Free shipping & 20% discount from 25€
20% discount from €25
Excluded: Promotional goods, furniture, appliances, UV wraps, sets, vouchers
Go to homepage
Cart
active language icon ENG language select icon
ProductNo: 15414

Jolifin LAVENI UVA tube - Universal 9 Watt

in stock
24h Express delivery
€4.95*
From 4 units:
€3.20*
Need help? We are available
for you 7 days a week.
Secure shopping.
30 day return policy
active language icon ENG language select icon

Jolifin LAVENI UVA Tube - Universal 9 Watt for perfect nail modelling

Jolifin LAVENI UVA Tube - Universal 9 Watt is indispensable for your nail modelling. The 2-pin system offers excellent curing of UV gels. This tube fits into the Jolifin LAVENI UVA light curing device - Infinity and all standard 2-pin UV devices. It cures with an average wavelength of 365 nanometres.

Characteristics:

  • 2pin system
  • 9 watts
  • 365 nanometres

This tube fits into the Jolifin LAVENI UVA light curing device - Infinity and all standard 2Pin UV devices.

Curing: UVA
Variant: Curing
Vegan: Yes
active language icon ENG language select icon

Replacing the tubes:

If the appliance does not start, this is usually due to a defective tube and only very rarely to a fault in the appliance. In the appliance, the two sockets on one side are always connected in pairs, i.e. top and bottom left and top and bottom right. This means that if a tube is defective, two sockets will not light up, i.e. one side. If there is a defective tube on each side, the entire device will not switch on.

To find the fault or the defective tube, proceed as follows:

If one side fails:

Move the tubes within the appliance one place at a time. If the failed tube pair changes at the latest on the second reconnection, the last tube plugged in is defective. This tube usually also rattles. Replacing tubes in pairs does not help because, as described above, the parallel connection only shifts the problem from one side to the other.

In the event of complete failure:

First swap the two upper tubes with each other, then swap one of the lower tubes with one of the upper tubes of the other pair of tubes. If nothing still works, either more than two tubes or the appliance is faulty. Unfortunately, it is not possible to find out without another set of test tubes. In the event of an actual defect in the tubes or the appliance, please contact us so that we can clarify the next steps with our staff.

active language icon ENG language select icon

0 of 0 reviews

Leave a review!

Share your experiences with other customers.

active language icon ENG language select icon
Questions & Answers

Your question can be answered either by us, by manufacturers or by our customers.

active language icon
Change language setting:
Cancel